The manufacturer of the BOT-3000E digital tribometer is Regan Scientific Instruments of Carrollton (Dallas), Texas. Recently we asked Regan for an update on ANSI B101.3, “Test Method for Measuring Wet DCOF of Common Hard-Surface Floor Materials,” approved January 18, 2012, and ANSI/NFSI B101.1. We received a reply from Peter Ermish, President. Here’s part of his … Continue reading “BOT-3000E Manufacturer Advises Against Using ANSI/NFSI B101.3 and B101.1 to Assess Floor Slip Resistance”
Category: Slip Resistance Testing
Maximum Coefficient of Friction is not Limited to 1.00
It’s sometimes assumed that coefficient of friction (COF) has a maximum theoretical and practical value of 1.00. This isn’t true; there is no maximum. It is true that values exceeding 1.00 are so slip-resistant that their actual value is often of little interest. Some COF measuring instruments, such as BOT-3000E and English XL, are not … Continue reading “Maximum Coefficient of Friction is not Limited to 1.00”
Germany’s DIN 51130 Slip Test: What’s it Good For?
In Europe, a slip resistance test for flooring is prescribed by German Institute for Normalization (DIN) standard DIN 51130. A person wearing industrial-type treaded shoes walks, facing down slope, on a variable-angle ramp which has the flooring to be tested on it. The flooring is coated with motor oil. The walker (without holding the handrails) … Continue reading “Germany’s DIN 51130 Slip Test: What’s it Good For?”
SlipAlert Dynamic Floor Friction (DCOF) Test Instrument for $2380!
The SlipAlert dynamic coefficient of friction (DCOF) tester has been in wide use for many years but now is offered by Safety Direct America for a limited time at close to half of its previous price! A roller-coaster type of dynamic floor slip resistance tester, SlipAlert’s (now known as the iAlert – same tribometer with … Continue reading “SlipAlert Dynamic Floor Friction (DCOF) Test Instrument for $2380!”
Many Polished Concrete Floors are Slippery when Wet
Can polished concrete floors be slippery when wet? Several web sites say yes, but others (mostly polished concrete vendors) say no, it only looks that way. A study of polished concrete published by the American Society of Concrete Contractors (ASCC) in Concrete International shows wet dynamic coefficients of friction (DCOF) as measured by ANSI A137.1 … Continue reading “Many Polished Concrete Floors are Slippery when Wet”
A Review of Standards for Pedestrian Slip Resistance Testing
There are a number of floor slip test methods established by standards-setting organizations that assess pedestrian slip resistance. Here we’ll review the most widely known and current ones. They are distinguished by the devices used in the testing. Terms such as DCOF rating, coefficient of friction, slip coefficient, slip resistance rating, and friction coefficient all … Continue reading “A Review of Standards for Pedestrian Slip Resistance Testing”
New Study Shows Sotter Engineering to be one of World’s Most Accurate Pendulum Floor Slip Test Labs
A recent global interlaboratory program “Slip Resistance Proficiency Testing — Pendulum Friction Tester,” showed Sotter Engineering Corporation’s Safety Direct America (SDA) floor slip resistance testing laboratory to be one of the world’s most accurate in use of the pendulum skid tester. The pendulum is a national standard for pedestrian floor and tile slip resistance testing … Continue reading “New Study Shows Sotter Engineering to be one of World’s Most Accurate Pendulum Floor Slip Test Labs”
Financial losses from slip and fall accidents
Slip and fall accidents are the #1 reason Americans show up at emergency rooms, according to data from the CDC. Slippery floors are a silent epidemic in America, and lawsuits are filed daily across the nation involving major injuries and deaths from slippery floors. Unless the negligent party is the victim’s employer, the victim of … Continue reading “Financial losses from slip and fall accidents”
Floor Slip Rating: SCOF vs. DCOF
Static coefficient of friction (SCOF) was formerly used to measure the slip resistance of a wet floor in the USA, but the test method (ASTM C1028) was withdrawn by the ASTM in 2014. Experts in the USA now know to use dynamic coefficient of friction (DCOF), as the rest of the world has been using … Continue reading “Floor Slip Rating: SCOF vs. DCOF”
ANSI A326.3 Acutest Does Not Predict Likelihood of Slip
A widely used floor friction test, American National Standards Institute A326.3, states in its introduction that “it can provide a useful comparison of surfaces, but it does not predict the likelihood a person will or will not slip on a hard surface flooring material.” The test assesses wet dynamic coefficient of friction (DCOF) using the … Continue reading “ANSI A326.3 Acutest Does Not Predict Likelihood of Slip”