The American National Standards Institute (ANSI) is issuing a new test method, with minimum dynamic coefficient of friction (DCOF rating), for slip resistance of hard flooring materials, wet or dry, laboratory or field testing. No minimum DCOF is provided for exterior applications. The BOT-3000E digital tribometer is used for the testing. The Secretariat for the … Continue reading “ANSI Issuing Another Standard Slip Test Method for Flooring Materials”
Tag: anti-slip floor
Proposed Federal Rule for Floor Slip Resistance
The U.S. federal government’s Consumer Product Safety Commission (CPSC) is considering a petition requesting rule making to require that manufacturers of floor coverings, floor coverings with coatings, and treated floor coverings label their products’ slip resistance in accordance with an ANSI/National Floor Safety Institute (NFSI) standard, B101.5. (NFSI, Safety Direct America and others offer for-fee … Continue reading “Proposed Federal Rule for Floor Slip Resistance”
Video Explains IBC Requirements for Floor Slip Resistance
The 2012 International Building Code changed slip resistance requirements for indoor floors that may get wet in use. The previously-used ASTM C 1028 friction test method is obsolete, and testing using the AcuTest method in ANSI A137.1 slip test must show a minimum of 0.42 wet dynamic coefficient of friction — but many other factors … Continue reading “Video Explains IBC Requirements for Floor Slip Resistance”
Improving the World’s Most Sophisticated Floor Slip-Resistance Safety Standards
In June’s post we discussed situation-specific slip resistance safety standards, which reflect the use or function of a floor and the friction (coefficient of friction) demands placed on it. Many U.S. floor friction standards are “one size fits all” — for instance, a wet dynamic coefficient of friction (DCOF) of 0.43 is considered adequate for … Continue reading “Improving the World’s Most Sophisticated Floor Slip-Resistance Safety Standards”
Misleading ASTM C 1028 Friction Test Continues to Wreak Havoc in the USA
Misguided investments of hundreds of millions of dollars in slippery flooring … pain, suffering, and financial losses to accident victims and their families … lawsuits by the thousands … and lack of consumer confidence in ceramic tile and other hard flooring: these are some of the consequences of a poorly-conceived floor “slip-resistance” test — ASTM … Continue reading “Misleading ASTM C 1028 Friction Test Continues to Wreak Havoc in the USA”